  gha-2 gha300f ac-dc power supplies medical type gh a 300 f - oo - o ordering information r 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional * 6 t3 : mounting hole m3 j1 : vh(j.s.t.)connector type r3 : with subfeatures ( 5vaux,12vaux,remote, power good) specification is changed at option, refer to instruction manual. recommended emi/emc filter eac-10-472 high voltage pulse noise type : eap series low leakage current type : eam series * the emi/emc filter is recommended to connect with several devices. 2 cautions 3 y~ forced air cooling is required for the maximum output power. please see instruction manual. y~ this power supply requires mounting on metal standoffs 5mm in height. insulation sheet is required if standoff is not used or l ess than 5mm clearance is needed. y~ avoid applying stress to surface mount components. y~ de-rating is required if the applied input voltage is 90-115vac. y~ the electrolytic capacitor has limited life span which is very much dependent on the actual operating conditions. y~ operating in the presense of chemical vapors or harsh environmnet can affect the power supply life expectnacy. y~ please make sure to read the instruction manual carefully before using this product. y it should be in the "instruction manual" not spec sheet. model gha300f-12 gha300f-24 gha300f-48 max output wattage[w] 300 300 302.4 dc output forced air at 50 c 12v 25a 24v 12.5a 48v 6.3a convection at 40 c 12v 8.4a 24v 4.2a 48v 2.1a at 50 c 12v 4.5a 24v 2.2a 48v 1.1a specifications model gha300f-12 gha300f-24 gha300f-48 input voltage[v] ac90 - 264 1 f (output derating is required at ac90v -115v * 3 ) current[a] acin 120v 3.3typ acin 230v 1.8typ frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 120v 89typ 90typ 90typ acin 230v 91typ 92typ 92typ power factor (io=100%) acin 120v 0.95typ acin 230v 0.90typ inrush current[a] acin 120v 20typ (io=100%) (at cold start) (ta=25 c ) acin 230v 40typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.125/0.250max (acin 120v/240v 60hz,io=100%, according to iec60601-1) output voltage[v] 12 24 48 current[a] forced air 25 12.5 6.3 convection 4.5 2.2 1.1 line regulation[mv] * 4 48max 96max 192max load regulation[mv] * 4 100max 150max 240max ripple[mvp-p] * 1 0 to +50 c 240max 240max 300max -20 to 0 c 320max 320max 400max ripple noise[mvp-p] * 1 0 to +50 c 300max 300max 480max -20 to 0 c 360max 360max 500max temperature regulation[mv] 0 to +50 c 120max 240max 480max -20 to +50 c 150max 290max 600max drift[mv] * 2 48max 96max 192max start-up time[ms] 500typ (acin 120v, io=100%) hold-up time[ms] 16typ (acin 120v, io=100%) output voltage adjustment range[v] 10.80 to 13.20 21.60 to 26.40 43.20 to 52.80 output voltage setting[v] 12.00 to 12.48 24.00 to 24.96 48.00 to 49.92 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection[v] 13.80 to 16.80 27.60 to 33.60 55.20 to 67.20 aux1 (12v1a) optional aux2 (5v1a) optional remote on/off optional powergood optional isolation input-output - rc - aux * 7 ac4,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output - rc - aux-fg * 7 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) output - rc - aux * 7 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -20 to +70 c , 20 - 90%rh (non condensing) storage temp.,humid.and altitude -30 to +75 c , 20 - 90%rh (non condensing) vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, ansi/amii es60601-1, c-ul, en60950-1, en60601-1 conducted noise complies with fcc-b, vcci-b, cispr11-b, cispr22-b, en55011-b, en55022-b harmonic attenuator complies with iec61000-3-2 (class a) * 5 others case size/weight 76.2 x 35 x 127mm [3.0 x 1.4 x 5.0 inches] (w x h x d) / 400g max cooling method convection, forced air (require external fan) photo is an image of the appearance. may differ from the actual product. information the home page is the latest. * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 please contact us about dynamic load and input response. * 5 please contact us about another class. * 6 specification is changed at option, refer to instruction manual. * 7 applicable when aux and remote control (optional) is added. * to meet the specifications. do not operate over-loaded condition. * sound noise may be generated by power supply in case of pulse load. * parallel operation is not possible. gha n f @ h i b  j o e e    ( ) "   nf hib joee ()"                         
gha-3 gha300f external view features block diagram - high power density:14.3w/inch 3 - high efficiency 92 ? typ (input voltage 230v, output voltage 24v) -  " x  "standard footprint - fits 1u applications - industrial and medical safety app rovals - low leakage current - with remote on/off (optional) - with aux1 (5v), aux2 (12v) (optional) - no minimum load is required noise filter fuse 250v10a x 2 a c in 90 - 264v fg booster inducter current sensing dc out rectifier and filter aux2(5v 1a) aux1(12v 1a) rc(remote on/off) inverter rectifier inrush current limit rectifier and filter control inverter current sensing internal regulator rectifier and filter rectifier and filter over voltage protection control control pg(power good) photocoupler photocoupler transformer transformer i/oconnector mating connector terminal mfr cn101 a-41671-a03a197-2 09-50-8031 08-50-0105 08-65-0114 molex cn501  optional  087831-0820 51110-0851 50394-8051 cn101  optional  b2p3-vh vhr-3n svh-21t-p1.1 j.s.t. cn501  optional  b8b-phdss phdr-08vs sphd-002t-p0.5 fg mating connector terminal mfr - 250 series - 170603-2 tyco electronics pin no. function 1 aux1 : aux1  12v1a) 2 aux1g : aux1  gnd) 3 rc1 : remote on/off 4 rcg : remote on/off  gnd) 5 pg : power good 6 pgg : power good  gnd  7 aux2 : aux2  5v1a) 8 aux2g : aux2  gnd) pin no. input 1 ac(l) 2 3 ac(n) 3 1 fg ac(l) ac(n) cn101 tb502 tb501 16.5 24.5 35 124.1 119.7 127.0 115.6 5.7 5.7 64.8 76.2 38.0 18.0 17.0 output(+) output( - ) 1 2 7 8 with subfeatures(optional) voltage adjust mounting holes 4- f 3.4(with mounting holes m3) name plate [3.00] [2.55] [1.38] [0.22] [0.67] [1.50] [0.71] [4.71] [0.22] [4.55] [4.89] [5.00] [0.65] [0.96] cn501 ? tolerance 1 [ 0.04] ? weight : 400g max ? there is a total of four attachment holes. ? this power supply requires mounting on metal standoffs 5mm in height. (insulating sheet is required if you do not use a spacer). ? dimensions in mm, [ ]=inches ? screw tightening torque : (tb501, 502) : 1.5n - m max ? mounting toque : 0.6n - m max ? avoid contact between tb501 and 502 wiring with mounting parts. ? option : -j1 : (j.s.t) connector type. refer to instruction manual 5. 0.5 0.5 1 2 7 8 cn501 gha n f @ h i b  j o e e    ( ) "   nf hib joee ()"                         
gha-4 GHA500F ac-dc power supplies medical type gh a 500 f - oo - o ordering information r 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional * 6 t3 : mounting hole m3 j1 : vh(j.s.t.)connector type r3 : with subfeatures ( 5vaux,12vaux,remote, power good) p : pallarel operation specification is changed at option, refer to instruction manual. recommended emi/emc filter eac-10-472 high voltage pulse noise type : eap series low leakage current type : eam series * the emi/emc filter is recommended to connect with several devices. 2 cautions 3 y~ forced air cooling is required for the maximum output power. please see instruction manual. y~ avoid applying stress to surface mount components. y~ de-rating is required if the applied input voltage is 90-115vac. y~ the electrolytic capacitor has limited life span which is very much dependent on the actual operating conditions. y~ operating in the presense of chemical vapors or harsh environmnet can affect the power supply life expectnacy. y~ please make sure to read the instruction manual carefully before using this product. y it should be in the "instruction manual" not spec sheet. model GHA500F-12 GHA500F-15 GHA500F-24 GHA500F-48 max output wattage[w] 500.8 501 504 504 dc output forced air at 50 c 12v 41.7a 15v 33.4a 24v 21.0a 48v 10.5a convection at 40 c 12v 12.5a 15v 10.0a 24v 6.3a 48v 3.2a at 50 c 12v 9.2a 15v 7.4a 24v 4.6a 48v 2.3a conduction cooling at 0 c 12v 30.0a 15v 24.0a 24v 15.0a 48v 7.5a at 50 c 12v 16.7a 15v 13.4a 24v 8.4a 48v 4.2a specifications model GHA500F-12 GHA500F-15 GHA500F-24 GHA500F-48 input voltage[v] ac90 - 264 1 f (output derating is required at ac90v -115v * 3 ) current[a] acin 120v 5.4typ acin 230v 2.9typ frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 120v 88typ 90typ 90typ 90typ acin 230v 90typ 92typ 92typ 92typ power factor (io=100%) acin 120v 0.95typ acin 230v 0.90typ inrush current[a] acin 120v 20typ (io=100%) (at cold start) (ta=25 c ) acin 230v 40typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.125/0.250max (acin 120v/240v 60hz,io=100%, according to iec60601-1) output voltage[v] 12 15 24 48 current[a] forced air 41.7 33.4 21.0 10.5 convection 9.2 7.4 4.6 2.3 conduction cooling 16.7 13.4 8.4 4.2 line regulation[mv] * 4 48max 60max 96max 192max load regulation[mv] * 4 100max 120max 150max 240max ripple[mvp-p] * 1 0 to +50 c 240max 240max 240max 300max -20 - 0 c 320max 320max 320max 400max ripple noise[mvp-p] * 1 0 to +50 c 300max 300max 300max 480max -20 - 0 c 360max 360max 360max 500max temperature regulation[mv] 0 to +50 c 120max 120max 240max 480max -20 to +50 c 150max 150max 290max 600max drift[mv] * 2 48max 60max 96max 192max start-up time[ms] 500typ (acin 120v, io=100%) hold-up time[ms] 16typ (acin 120v, io=100%) output voltage adjustment range[v] 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 43.20 to 52.80 output voltage setting[v] 12.00 to 12.48 15.00 to 15.30 24.00 to 24.96 48.00 to 49.92 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection[v] 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 55.20 to 67.20 aux1 (12v1a) optional aux2 (5v1a) optional remote on/off optional powergood optional isolation input-output - rc - aux * 7 ac4,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output - rc - aux-fg * 7 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) output - rc - aux * 7 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -20 to +80 c , 20 - 90%rh (non condensing) storage temp.,humid.and altitude -30 to +80 c , 20 - 90%rh (non condensing) vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, ansi/amii es60601-1, c-ul, en60950-1, en60601-1 conducted noise complies with fcc-b, vcci-b, cispr11-b, cispr22-b, en55011-b, en55022-b harmonic attenuator complies with iec61000-3-2 (class a) * 5 others case size/weight 76.2 x 35 x 127mm [3.0 x 1.4 x 5.0 inches] (w x h x d) / 420g max cooling method convection, forced air (require external fan), conduction cooling photo is an image of the appearance. may differ from the actual product. information the home page is the latest. * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 please contact us about dynamic load and input response. * 5 please contact us about another class. * 6 specification is changed at option, refer to instruction manual. * 7 applicable when aux and remote control (optional) is added. * to meet the specifications. do not operate over-loaded condition. * sound noise may be generated by power supply in case of pulse load. * parallel operation is not possible. gha n f @ h i b  j o e e    ( ) "   nf hib joee ()"                         
gha-5 GHA500F external view features block diagram - wattage 500w max - high power density:24.1w/inch 3 - high efficiency 92 ? typ (input voltage 230v,output voltage 24v) - conduction cooling -  " x  "standard footprint - fits 1u applications - industrial and medical safety app rovals - low leakage current - with remote on/off (optional) - with aux1 (5v), aux2 (12v) (optional) - no minimum load is required noise filter fuse 250v10a x 2 a c in 90 - 264v fg booster inducter current sensing dc out rectifier and filter aux2(5v 1a) aux1(12v 1a) rc(remote on/off) inverter rectifier inrush current limit rectifier and filter control inverter current sensing internal regulator rectifier and filter rectifier and filter over voltage protection control control pg(power good) photocoupler photocoupler transformer transformer i/oconnector mating connector terminal mfr cn101 a-41671-a03a197-2 09-50-8031 08-50-0105 08-65-0114 molex cn501  optional  087831-0820 51110-0851 50394-8051 cn101  optional  b2p3-vh vhr-3n svh-21t-p1.1 j.s.t. cn501  optional  b8b-phdss phdr-08vs sphd-002t-p0.5 fg mating connector terminal mfr - 250 series - 170603-2 tyco electronics pin no. function 1 aux1 : aux1  12v1a) 2 aux1g : aux1  gnd) 3 rc1 : remote on/off 4 rcg : remote on/off  gnd) 5 pg : power good 6 pgg : power good  gnd  7 aux2 : aux2  5v1a) 8 aux2g : aux2  gnd) pin no. input 1 ac(l) 2 3 ac(n) 1 2 7 8 ? tolerance 1 [ 0.04] ? weight : 420g max ? there is a total of four attachment holes. ? base plate : aluminum ? dimensions in mm, [ ]=inches ? screw tightening torque : (tb501, 502) : 1.5n - m max ? mounting toque : 0.6n - m max ? avoid contact between tb501 and 502 wiring with mounting parts. ? option : -j1 : (j.s.t) connector type. refer to instruction manual 5. 3 1 fg ac(l) ac(n) cn101 tb502 tb501 16.5 24.5 35 124.1 119.7 127.0 115.6 5.7 5.7 64.8 76.2 38.0 18.0 17.0 output(+) output( - ) 1 2 7 8 with subfeatures(optional) voltage adjust mounting holes 4- f 3.4(with mounting holes m3) name plate [3.00] [2.55] [1.38] [0.22] [0.67] [1.50] [0.71] [4.71] [0.22] [4.55] [4.89] [5.00] [0.65] [0.96] cn501 0.5 0.5 cn501 gha n f @ h i b  j o e e    ( ) "   nf hib joee ()"                         